I have messed around with NUT to trigger a graceful shutdown of my home server running Ubuntu Server. I have struggled with setting NUT up on bare metal, but would like a gui anyway. I saw PVE-UPS which looks good, but I think but I think it is meant for Proxmox. Any alternatives, or a spin of PVE-UPS for docker compose anybody know about?


It’s a lot. But here are my most recent notes.
Note that the pipe & lock locations different by distro, as does the nut username. So these files won’t drop in and work anywhere.
The dummy driver will need to be installed and configured.
Mine also have several layers of timers on battery an online:
Most configs would have the client side cancel their timers if power returns. In my case I don’t want that because I prefer more certainty of state so that I know it’s safe to power cycle an outlet to bring a device back up. My NUT server runs on an old pi 3b with a read-only file system. So it never needs a safe shutdown. It’s the last man standing to bring everything else back up if the UPS returns to line power before the battery is exhausted. That’s why there is no local shutdown on the NUT server config.
Each
snmpset...is a truncated version of an outlet power command.Also, the wall commands were a debug aid. Uncomment to use, but test a command first. Wall doesn’t work on some distros.
NUT Server
NUT.CONF:
MODE=netserverUPS.CONF:
[ups] desc = My UPS driver = dummy-ups port = /opt/ups/ups.seqUPSD.CONF:
LISTEN 0.0.0.0 3493 ## all interfaces ## STATEPATH /var/run/nutUPSD.USERS:
[upsuser] password = <pw> actions = set upsmon master [upssrv] password = <pw> actions = set upsmon slave [upspi] password = <pw> actions = set upsmon slaveUPSMON.CONF:
RUN_AS_USER nut #RUN_AS_USER root MONITOR ups@localhost 1 upsuser <pw> master NOTIFYMSG ONLINE "UPS %s on line power" NOTIFYMSG ONBATT "UPS %s on battery" NOTIFYMSG LOWBATT "UPS %s battery is low" NOTIFYMSG FSD "UPS %s: forced shutdown in progress" NOTIFYMSG COMMOK "Communications with UPS %s established" NOTIFYMSG COMMBAD "Communications with UPS %s lost" NOTIFYMSG SHUTDOWN "Auto logout and shutdown proceeding" NOTIFYMSG REPLBATT "UPS %s battery needs to be replaced" NOTIFYMSG NOCOMM "UPS %s is unavailable" NOTIFYMSG NOPARENT "upsmon parent process died - shutdown impossible" NOTIFYFLAG ONLINE WALL+EXEC+SYSLOG NOTIFYFLAG ONBATT WALL+EXEC+SYSLOG NOTIFYFLAG LOWBATT SYSLOG+WALL NOTIFYFLAG FSD SYSLOG+WALL NOTIFYFLAG COMMOK SYSLOG+WALL NOTIFYFLAG COMMBAD SYSLOG+WALL NOTIFYFLAG SHUTDOWN SYSLOG+WALL NOTIFYFLAG REPLBATT SYSLOG+WALL NOTIFYFLAG NOCOMM SYSLOG+WALL NOTIFYFLAG NOPARENT SYSLOG+WALL MINSUPPLIES 1 SHUTDOWNCMD "/sbin/shutdown -P +0" NOTIFYCMD "/usr/sbin/upssched" POLLFREQ 5 POLLFREQALERT 5 HOSTSYNC 15 DEADTIME 15 # POWERDOWNFLAG /var/run/killpower RBWARNTIME 43200 NOCOMMWARNTIME 300 FINALDELAY 5 CERTVERIFY 0 FORCESSL 0 UPSSCHED.CONF: CMDSCRIPT /etc/nut/upssched-cmd PIPEFN /var/run/nut/upssched.pipe LOCKFN /var/run/nut/upssched.lock AT ONBATT ups@localhost CANCEL-TIMER online3 AT ONBATT ups@localhost CANCEL-TIMER online10 AT ONBATT ups@localhost START-TIMER onbatt5 300 AT ONBATT ups@localhost EXECUTE onbattnotify AT ONLINE ups@localhost CANCEL-TIMER onbatt5 AT ONLINE ups@localhost START-TIMER online3 180 AT ONLINE ups@localhost START-TIMER online10 600 AT ONLINE ups@localhost EXECUTE onlinenotifyUPSSCHED-CMD
#! /bin/bash # # This script should be called by upssched via the CMDSCRIPT directive # The first argument passed to your CMDSCRIPT is the name of the timer # from your AT lines. logger -t upssched-cmd "Calling upssched-cmd $1" wall "Calling upssched-cmd $1" UPS="ups@localhost" HOST=$( uname -n) TIMESTAMP=$(date +%Y%m%d%H%M%S) STATUS=$( upsc $UPS ups.status ) CHARGE=$( upsc $UPS battery.charge ) CHMSG="UPS[STATUS]:$CHARGE%" case $1 in onbattnotify) # srv and pi are upsmon clients and will shut down on their own after a 30s delay. # Log the Notification. logger -t upssched-cmd "UPS on Battery Power. Servers will shutdown in 30 seconds. Switch shutdown in 5 minutes. $CHMSG $TIMESTAMP" wall "upssched-cmd onbattnotify: UPS on Battery Power. Servers will shutdown in 30 seconds. Switch shutdown in 5 minutes. $CHMSG" # wall "upssched-cmd: sleeping to give servers time to poweroff" sleep 120s # Power off PDU outlets to save power. logger -t upssched-cmd "UPS on Battery Power. PDU outlets 4-srv-drives, 5-srv, 7-pi and 8-homeassistant power down NOW. $CHMSG $TIMESTAMP" snmpset ... snmpset ... snmpset ... snmpset ... # wall "End upssched-cmd $1" ;; onbatt5) # Shut down servers logger -t upssched-cmd "UPS on Battery Power. PDU outlets 3-switch and 8-homeassistant power down NOW. $CHMSG $TIMESTAMP" snmpset ... snmpset ... # wall "End upssched-cmd $1" ;; onlinenotify) # Log the notification. logger -t upssched-cmd "UPS back on Line Power. Bringing up network in 3 minutes, servers in 10 minutes. $CHMSG $TIMESTAMP" # wall "End upssched-cmd $1" ;; online3) # Power on PDU outlets for main switch to prep for server startup. logger -t upssched-cmd "UPS back on Line Power. Bringing up PDU outlet 3-switch NOW. $CHMSG $TIMESTAMP" snmpset ... # wall "End upssched-cmd $1" ;; online10) # Power on PDU outlets for servers now. logger -t upssched-cmd "UPS on Line Power. Bringing up PDU outlets 5-srv, 7-pi, 8-homeassistant NOW. $CHMSG $TIMESTAMP" snmpset ... snmpset ... snmpset ... # wall "End upssched-cmd $1" ;; upsgone) logger -t upssched-cmd "UPS communication has been gone awhile on $HOST. $TIMESTAMP" ;; ) logger -t upssched-cmd "Unrecognized command: $1" ;; esacNUT Client
NUT.CONF
MODE=netclientUPS.CONF
maxretry = 3UPSD.CONF
# emptyUPSD.USERS
# emptyUPSMON.CONF
RUN_AS_USER nut MONITOR ups@192.168.0.77 1 upspi <pw> slave NOTIFYCMD /usr/sbin/upssched SHUTDOWNCMD "sudo /sbin/shutdown -P +0" NOTIFYMSG ONLINE "UPS %s on line power" NOTIFYMSG ONBATT "UPS %s on battery" NOTIFYMSG LOWBATT "UPS %s battery is low" NOTIFYMSG FSD "UPS %s: forced shutdown in progress" NOTIFYMSG COMMOK "Communications with UPS %s established" NOTIFYMSG COMMBAD "Communications with UPS %s lost" NOTIFYMSG SHUTDOWN "Auto logout and shutdown proceeding" NOTIFYMSG REPLBATT "UPS %s battery needs to be replaced" NOTIFYMSG NOCOMM "UPS %s is unavailable" NOTIFYMSG NOPARENT "upsmon parent process died - shutdown impossible" NOTIFYFLAG ONLINE WALL+EXEC+SYSLOG #+SYSLOG+WALL NOTIFYFLAG ONBATT WALL+EXEC+SYSLOG #+SYSLOG+WALL NOTIFYFLAG LOWBATT SYSLOG+WALL NOTIFYFLAG FSD SYSLOG+WALL NOTIFYFLAG COMMOK SYSLOG+WALL NOTIFYFLAG COMMBAD SYSLOG+WALL NOTIFYFLAG SHUTDOWN SYSLOG+WALL NOTIFYFLAG REPLBATT SYSLOG+WALL NOTIFYFLAG NOCOMM SYSLOG+WALL NOTIFYFLAG NOPARENT SYSLOG+WALL MINSUPPLIES 1 POLLFREQ 10 POLLFREQALERT 5 HOSTSYNC 15 DEADTIME 15 RBWARNTIME 43200 NOCOMMWARNTIME 300 FINALDELAY 5UPSSCHED.CONF
CMDSCRIPT /etc/nut/upssched-cmd PIPEFN /run/nut/upssched.pipe LOCKFN /run/nut/upssched.lock AT ONBATT ups@192.168.0.77 EXECUTE onbattnotify AT ONBATT ups@192.168.0.77 START-TIMER onbatt30s 30 # Disabled the online cancel actions in favor of having certainty on the state. # Servers will go down on an OB event, but that's fine. When Nutpi sees it back # OL it will bring up the servers #AT ONLINE [email protected] CANCEL-TIMER onbatt30s #AT ONLINE [email protected] EXECUTE onlinenotifyUPSSCHED-CMD
#! /bin/sh # # This script should be called by upssched via the CMDSCRIPT directive. # # The first argument passed to your CMDSCRIPT is the name of the timer # from your AT lines. logger -i -t upssched-cmd "Calling upssched-cmd $1" UPS="ups@192.168.0.77" HOST=$( uname -n) STATUS=$( upsc $UPS ups.status 2>&1 | grep -v '^Init SSL' ) CHARGE=$( upsc $UPS battery.charge 2>&1 | grep -v '^Init SSL' ) CHMSG="$UPS[$STATUS]:$CHARGE%" case $1 in onbattnotify) # Log the Notification. logger -t upssched-cmd "UPS on Battery Power. Shutting down $HOST in 30 seconds. $CHMSG" wall "upssched-cmd: UPS on Battery Power. Shutting down $HOST in 30 seconds. $CHMSG" ;; onbatt30s) # Shut down servers logger -t upssched-cmd "UPS on Battery Power. $HOST shutting down NOW. $CHMSG" wall "upssched-cmd: UPS on Battery Power. $HOST shutting down NOW. $CHMSG" sudo shutdown -P +0 ;; # onlinenotify) # # Log the notification. # logger -t upssched-cmd "UPS back on Line Power. $HOST is already online. $CHMSG" # wall "upssched-cmd: UPS back on Line Power. $HOST is already online. $CHMSG" # ;; upsgone) logger -t upssched-cmd "UPS communication has been gone awhile on $HOST." ;; *) logger -t upssched-cmd "Unrecognized command: $1" ;; esac